openmed.multimodal.edf.read_edf and OpenMedKit's EDFReader.read decode caller-supplied EDF, continuous EDF+C and discontinuous EDF+D recordings locally. There are no provider calls, model assets, network access, file writes or clinical interpretations. This reader follows the EDF specification and EDF+ specification.

Windowed signals and gaps

from openmed.multimodal.edf import EdfLimits, read_edf

# recording_bytes is supplied by the caller; no path is recorded in the result.
result = read_edf(recording_bytes, start_seconds=5, end_seconds=6,
                  limits=EdfLimits(max_output_samples=100_000))
for record in result.records:
    for window in record.signals:
        integer_samples = window.digital_samples
        scaled_samples = window.physical_samples
report = result.report()
# Only an explicit human decision may authorize consequential handoff.
reviewed = result.reviewed(confirmed=True)
import OpenMedKit

let result = try EDFReader.read(recordingData, startSeconds: 5, endSeconds: 6)
let report = result.report()
let reviewed = try result.reviewed(confirmed: true)

Offsets are seconds from the withheld header start second, including the first EDF+ record's fractional-second offset. Windows are half-open [start, end); a sample exactly at the end is excluded. Each record retains its onset, duration and each signal's first sample index. Sample offset within a record is first_sample_index * record_duration / samples_per_record. Signals may have different sample rates. No resampling, lead normalization or clock alignment is performed. ADC conversion is:

physical_min + (integer_sample - digital_min)
             * (physical_max - physical_min) / (digital_max - digital_min)

Negative physical gain is supported. Integer samples must fall in their declared digital range when decoded. Samples outside the requested window are not decoded or range-checked. Header validity, record completeness, all EDF+ annotation syntax and all record timings are checked across the complete bounded recording.

record_onsets_seconds / recordOnsetsSeconds describes every data record. gaps describes every missing acquisition interval, even outside the window. For synthetic one-second records at offsets 0 and 5, the explicit gap is [1, 5). A [5, 6) window returns the second record only. Synthetic integer samples (2, 0, -1, -2) with digital range [-2, 2] and physical range [-1, 1] become (1, 0, -0.5, -1). These are engineering controls, not clinical validation.

EDF+D supports zero-duration point records with one sample per ordinary signal; their sampling rate is absent. Annotation-only EDF+ records are also supported. For zero-duration files the default window ends one second after the final point. Otherwise, omitting the end requests the recording's end, subject to the window budget. An explicit window may extend beyond the recording and return no samples when it covers only a gap or lies beyond acquisition.

Withheld content and review

Patient and recording identification, start date/time, transducer, prefilter and reserved fields are never returned. Identification exposes only presence and absent, placeholder_only or not_verified status. Only exact EDF+ placeholders X X X X and Startdate X X X X receive placeholder_only; extra subfields do not. Placeholders can mean unknown information and do not prove anonymization.

Signal indices, physical/digital ranges, samples per record and sampling rates are available. Exact controlled labels (ECG, EEG, EMG, EOG, Temp rectal, Body temp, SaO2, SpO2, ECG I/II/III/aVR/aVL/aVF/V1–V6, EEG Fpz-Cz, EEG Pz-Oz) are preserved without normalization. Arbitrary labels become withheld. Physical dimensions are limited to V, mV, uV, nV, degreeC, %, Ohm and mmHg; other dimensions become withheld. This prevents accidental free-text header disclosures without inferring patient or lead identity.

Annotation-channel sample bytes are never exposed. Each nonempty annotation list (TAL) contributes only its record/signal index, onset, optional duration and count of nonempty annotations. Empty timekeeping annotations are excluded from counts. Lists are selected by onset within the window, or positive duration overlapping it, even when their containing record is outside the window. Negative event onsets are allowed. Annotation text must be valid UTF-8 and is discarded after syntax validation. Timekeeping in the first annotation channel is mandatory for every EDF+ record; missing timing, overlaps, backward timing and discontinuities in EDF+C fail closed.

Every result and report carries a non-diagnostic notice. reviewed(confirmed=True) (or Swift's reviewed(confirmed: true)) binds explicit reviewer confirmation; false confirmation fails with edf_review_required. Downstream consequential consumers must enforce that state. This reader makes no clinical decision. Waveform samples remain sensitive, even though these headers are withheld. Reports contain controlled counts/statuses and the notice, omitting samples, labels, absolute dates and annotation text. Error messages contain only reason codes; underlying stream messages and Python exception chains are withheld.

Bounds and streams

Default budgets are 64 MiB input, 64 signals, 100,000 records, 1 MiB per record, 86,400 seconds maximum acquisition offset/end, 3,600 seconds per window, 1,000,000 retained samples and 100,000 annotation lists (including timekeepers). Callers can supply positive budgets; unknown record count -1 is determined from complete bounded records at EOF. Timing fields are bounded to 28 ASCII characters; header exponents are bounded to ±12. EDF+ onset/duration fields use decimal syntax without exponents or spaces. Rational arithmetic in Python and bounded decimal arithmetic in Swift validate continuity before returning floating-point offsets. Long precision fields fail with edf_numeric_invalid.

Python accepts bytes and caller-owned binary streams. Seekable streams are restored on success/failure; nonseekable streams are consumed. Swift accepts Data and caller-opened InputStream, consuming the stream without closing it. Reads never exceed 64 KiB; an extra one-byte probe validates EOF at the exact input budget. At most one record and bounded annotation lists are parsed at a time, plus the selected output and content-free timing/gap index.

Stable failures include edf_header_invalid, edf_header_size_invalid, edf_numeric_invalid, edf_range_invalid, edf_samples_invalid, edf_sample_range_invalid, edf_record_count_invalid, edf_truncated, edf_annotation_header_invalid, edf_annotation_channel_missing, edf_annotation_invalid, edf_timekeeping_invalid, edf_record_timing_invalid, edf_duration_invalid, edf_window_invalid, edf_limits_invalid, edf_stream_read_error and Python's edf_stream_restore_error. Budget failures use edf_byte_limit, edf_signal_limit, edf_record_limit, edf_record_byte_limit, edf_duration_limit, edf_output_sample_limit and edf_annotation_limit.

The reader owns only parsing. Header/annotation redaction artifacts, ECG contract integration, lead normalization and provenance clock alignment remain separate capabilities. No release, model qualification or clinical-validation claim is made by successful decoding.